Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9507
Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9515
Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9520
Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9526
Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9536
Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9539
Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9559
Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9564
Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9585
Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9592 Custom products - Scandinavian Transformerhttps://www.st-t.pl/en/products/custom-products/52-toroidal-transformers-and-inductors2024-05-09T00:17:22+02:00TransElectroJoomla! - Open Source Content ManagementTOROIDAL TRANSFORMERS AND INDUCTORS2015-04-15T14:14:45+02:002015-04-15T14:14:45+02:00https://www.st-t.pl/en/products/custom-products/52-toroidal-transformers-and-inductors/88-toroidal-transformers-and-inductorsRené Alain Erichsen<p><img src="https://www.st-t.pl/images/Produkter/CustomProducts/AIR_COILS_1.jpg" /></p><p>Custimised toroidal transformers and inductors in sizes up to 20 KVA per phase. Sizes can be limited within the series due to the specific standard mounting parts. Special parts can be made.</p>
<p>Potted transformers are typical in standard boxes – special boxes can be made.</p>
<p>Industrial series UL marked (UL506) up to 5 kVA.</p>
<p>Medical series UL marked (UL60601-1) up to 10 kVA for 105°C and 130°C.</p>
<p>Current transformers</p>
<p>Special windings</p>
<p>Typical options are offered:</p>
<ul>
<li>UL class B insulation system for 130°C</li>
<li>UL class F insulation system for 155°C</li>
<li>UL class H insulation system for 180°C</li>
<li>Built-in fuse or fuse holder</li>
<li>Built-in thermal protection by thermal switch or thermal fuse</li>
<li>Clips</li>
<li>Connectors</li>
<li>Cable / cable with connector</li>
<li>DIN Rail mountings</li>
<li>Varnishing</li>
<li>Vacuum impregnation</li>
<li>Resin moulding in box (potting)</li>
<li>Vacuum moulded in box</li>
<li>Vertical / tall or horizontal / low profile design</li>
</ul>
<p>Toroidal transformers can be designed in different sizes (height and diameter) as well as additional primary and secondary voltages and outputs as required.</p>
<p>Toroidal transformers are characterized by being efficient, small and quiet / good EMC properties.</p>
<p>The circular core wound with steel ribbon combined with evenly distributed windings encapsulates the magnetic field, which enables an efficiency of about 95% to be achieved.</p>
<p>The high efficiency helps to make the transformer smaller and easier than the traditional EI transformer. UL approval according to UL506 or UL60601-1 possible.</p>
<p>All transformers are made according to EN61558 - unless otherwise agreed.</p>
<p>All transformers are tested before despatch.</p><p><img src="https://www.st-t.pl/images/Produkter/CustomProducts/AIR_COILS_1.jpg" /></p><p>Custimised toroidal transformers and inductors in sizes up to 20 KVA per phase. Sizes can be limited within the series due to the specific standard mounting parts. Special parts can be made.</p>
<p>Potted transformers are typical in standard boxes – special boxes can be made.</p>
<p>Industrial series UL marked (UL506) up to 5 kVA.</p>
<p>Medical series UL marked (UL60601-1) up to 10 kVA for 105°C and 130°C.</p>
<p>Current transformers</p>
<p>Special windings</p>
<p>Typical options are offered:</p>
<ul>
<li>UL class B insulation system for 130°C</li>
<li>UL class F insulation system for 155°C</li>
<li>UL class H insulation system for 180°C</li>
<li>Built-in fuse or fuse holder</li>
<li>Built-in thermal protection by thermal switch or thermal fuse</li>
<li>Clips</li>
<li>Connectors</li>
<li>Cable / cable with connector</li>
<li>DIN Rail mountings</li>
<li>Varnishing</li>
<li>Vacuum impregnation</li>
<li>Resin moulding in box (potting)</li>
<li>Vacuum moulded in box</li>
<li>Vertical / tall or horizontal / low profile design</li>
</ul>
<p>Toroidal transformers can be designed in different sizes (height and diameter) as well as additional primary and secondary voltages and outputs as required.</p>
<p>Toroidal transformers are characterized by being efficient, small and quiet / good EMC properties.</p>
<p>The circular core wound with steel ribbon combined with evenly distributed windings encapsulates the magnetic field, which enables an efficiency of about 95% to be achieved.</p>
<p>The high efficiency helps to make the transformer smaller and easier than the traditional EI transformer. UL approval according to UL506 or UL60601-1 possible.</p>
<p>All transformers are made according to EN61558 - unless otherwise agreed.</p>
<p>All transformers are tested before despatch.</p>