Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9507

Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9515

Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9520

Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9526

Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9536

Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9539

Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9559

Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9564

Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9585

Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/scantran/public_html/plugins/system/less/lessc/less.php/Less.php on line 9592
Custom products - Scandinavian Transformer https://www.st-t.pl/en/products/custom-products/54-cast-resin-transformers 2024-05-03T18:15:44+02:00 TransElectro Joomla! - Open Source Content Management CAST RESIN TRANSFORMERS 2015-04-15T14:14:45+02:00 2015-04-15T14:14:45+02:00 https://www.st-t.pl/en/products/custom-products/54-cast-resin-transformers/90-cast-resin-transformers René Alain Erichsen <p><img src="https://www.st-t.pl/images/Produkter/CustomProducts/CP_CAST_RESIN_TRANSFORMERS.jpg" /></p><p>Rating up to 2500 kVA and nominal voltage up to 36 kV.</p> <p>The transformers are built in accordance with IEC 726 standards.</p> <p>The core is built up of cold rolled oriented grain steel sheet with low specific losses, insulated on both sides by a thin inorganic coating (Carlyte). The sheets composing the core are cut at 45 degrees. Uniform pressing, stiffness and solidity of the columns assure a low noise level.</p> <p>The high voltage windings are made of electrolytic aluminum conductors (wire or foil strip depending upon power and voltage requirements). It is possible to produce copper windings. The windings are englobed under vacuum in class F epoxy resin. The accuracy of execution of these processes allows the obtainment of windings free from partial discharges.</p> <p>The low voltage windings are made of strip or foil (copper or aluminum conductors depending upon power and voltage requirements). Class H insulating material is used.</p> <p><strong>Standard accessories:</strong></p> <p>Skid under base or truck with bidirectional wheels.</p> <p>Lifting lungs.</p> <p>Earthen terminal.</p> <p>N° 3 PT100 probes.</p> <p><strong>Optional accessories:</strong></p> <p>Thermometer dial type with electric contacts.</p> <p>Temperature monitoring unit without display.</p> <p>Temperature monitoring unit with display.</p> <p>Fan ventilation.</p> <p>Fan drive unit.</p> <p>Anti vibration pad;</p> <p>Enclosure;</p> <p>Typical accessories are offered:</p> <ul> <li>UL class B insulation system for 130°C</li> <li>UL class&nbsp;F insulation system for 155°C</li> <li>UL class&nbsp;H insulation system for 180°C</li> <li>Built-in fuse or fuse holder</li> <li>Built-in thermal protection by thermal switch or thermal fuse</li> <li>Clips</li> <li>Connectors</li> <li>Cable / cable with connector</li> <li>DIN Rail mountings</li> <li>RAST5 bobbin</li> <li>Varnishing</li> <li>Vacuum impregnation</li> <li>Resin moulding in box (potting)</li> <li>Vacuum moulded in box</li> <li>Vertical / tall or horizontal / low profile design</li> </ul> <p>Cast resin transformer</p> <p>- Sizes up to 2500 kVA up to 36 kV nominal voltage.</p> <p>- Constructed according to IEC 726 standard.</p> <p>- Aluminum or copper windings.</p> <p>- Core of grain oriented electrode</p> <p>All transformers are made according to EN61558 - unless otherwise agreed.</p> <p>All transformers are tested before despatch.</p> <p><img src="https://www.st-t.pl/images/Produkter/CustomProducts/CP_CAST_RESIN_TRANSFORMERS.jpg" /></p><p>Rating up to 2500 kVA and nominal voltage up to 36 kV.</p> <p>The transformers are built in accordance with IEC 726 standards.</p> <p>The core is built up of cold rolled oriented grain steel sheet with low specific losses, insulated on both sides by a thin inorganic coating (Carlyte). The sheets composing the core are cut at 45 degrees. Uniform pressing, stiffness and solidity of the columns assure a low noise level.</p> <p>The high voltage windings are made of electrolytic aluminum conductors (wire or foil strip depending upon power and voltage requirements). It is possible to produce copper windings. The windings are englobed under vacuum in class F epoxy resin. The accuracy of execution of these processes allows the obtainment of windings free from partial discharges.</p> <p>The low voltage windings are made of strip or foil (copper or aluminum conductors depending upon power and voltage requirements). Class H insulating material is used.</p> <p><strong>Standard accessories:</strong></p> <p>Skid under base or truck with bidirectional wheels.</p> <p>Lifting lungs.</p> <p>Earthen terminal.</p> <p>N° 3 PT100 probes.</p> <p><strong>Optional accessories:</strong></p> <p>Thermometer dial type with electric contacts.</p> <p>Temperature monitoring unit without display.</p> <p>Temperature monitoring unit with display.</p> <p>Fan ventilation.</p> <p>Fan drive unit.</p> <p>Anti vibration pad;</p> <p>Enclosure;</p> <p>Typical accessories are offered:</p> <ul> <li>UL class B insulation system for 130°C</li> <li>UL class&nbsp;F insulation system for 155°C</li> <li>UL class&nbsp;H insulation system for 180°C</li> <li>Built-in fuse or fuse holder</li> <li>Built-in thermal protection by thermal switch or thermal fuse</li> <li>Clips</li> <li>Connectors</li> <li>Cable / cable with connector</li> <li>DIN Rail mountings</li> <li>RAST5 bobbin</li> <li>Varnishing</li> <li>Vacuum impregnation</li> <li>Resin moulding in box (potting)</li> <li>Vacuum moulded in box</li> <li>Vertical / tall or horizontal / low profile design</li> </ul> <p>Cast resin transformer</p> <p>- Sizes up to 2500 kVA up to 36 kV nominal voltage.</p> <p>- Constructed according to IEC 726 standard.</p> <p>- Aluminum or copper windings.</p> <p>- Core of grain oriented electrode</p> <p>All transformers are made according to EN61558 - unless otherwise agreed.</p> <p>All transformers are tested before despatch.</p>